Free lesson preview: EWIS Groups 1 & 2 — Recurrent
EWIS — AMC 20-22 — Target Groups 1 & 2 — Recurrent Knowledge Training
Lesson 1 of 12, exactly as learners see it. No sign-in needed; practice answers are not saved.
- 3.5 hours learning
- 12 questions, 18 min
- Certificate at 75 %
Lesson 1 of 12
Electrical safety and role boundaries
Scope, sources and author
Learning objective: Recognise an electrical hazard and preserve safety without unauthorised intervention.
Why the organisation needs this training
Regulation (EU) 2018/1139, Annex II, point 3.1(a), requires organisations to have the personnel, equipment, procedures and other means needed for their work. Regulation (EU) 1321/2014, Annex II (Part-145), 145.A.30(e), requires the organisation to establish and control personnel competence, including relevant safety management and human factors. AMC5 145.A.30(e)(a) says it should assess particular training needs, including EWIS; paragraph (b) points to AMC 20-22.
An implementing rule sets an obligation. An AMC describes an acceptable means of meeting the rule; GM explains it. Under AMC 20-22 section 8(b), refresher training should take place within a period not exceeding two years and follow the relevant target-group syllabus. It can review earlier learning and new material or publication revisions. This recommendation does not create a worldwide certificate-expiry rule.
EWIS means electrical wiring interconnection system: wires and devices transmitting electrical energy, data or signals between intended terminations, together with the specified connections, protection and supports. CS 25.1701 provides the detailed design definition and its equipment exclusions. For the maintainer, a damaged clamp or connector seal belongs in the assessment just as much as a damaged conductor.
Make the work area safe
Everyday example. A dark lamp does not prove that its supply cable is isolated.
At a line station, an engineer prepares to disconnect a cabin-light power unit (ATA 33) on a transport jet. The unlit reading light is the dark lamp. The engineer uses the current maintenance task to identify the circuit and all relevant sources, including batteries, external power, alternate feeds and stored energy. The task specifies switching, isolation, any discharge and verification. The engineer applies the prescribed warnings and isolation controls to prevent unintended energisation, tells affected teams and verifies the safe state before touching the connector.
Before applying power for a test, confirm the required aircraft configuration, clear people and equipment from affected systems, and coordinate with other work.
Training case: an access worker has used a harness as a handhold and a cable now has visible outer damage. Keep people clear while the responsible personnel make the circuit safe. After the prescribed verification, assess the wires, clamps and terminations that carried the load. A sound-looking outside surface cannot establish internal condition. Provide suitable access equipment; wire bundles are not steps, handholds or work-light supports (AMC 20-21 section 11(k)).
For smoke, arcing, unusual heat or a protection-device trip, use the aircraft and organisation’s immediate-response instructions. A previous successful reset is not a reason to feed an unresolved fault. Report the location, onset, power state, duration and actions taken, keeping observations separate from a suspected cause.
Electrical-shock awareness
If someone may still be in contact with electricity, do not touch them or enter the hazardous area. Raise the alarm, summon emergency assistance and have the supply made safe by someone able to do so safely. Do not improvise a rescue with metal tools. Once the electrical danger is removed, follow emergency-dispatch instructions and provide first aid within your training. This awareness supports, rather than replaces, practical first-aid training.
Sources: AMC 20-22 Appendix C, Module A, objectives (a) and syllabus 1; 145.A.45(a); AMC 20-21 section 11(k); NHS inform, electric-shock first aid.
Regulatory basis: what this course includes
This course teaches the sources below as amended up to the act or decision shown. Anything published after it is not part of this edition of the course.
| Source | Included up to |
|---|---|
| AMC 20-22 (EWIS training), Target Groups 1 & 2 | AMC-20 Amendment 23 (ED Decision 2022/001/R) (AMC 20-22 unchanged since ED Decision 2008/007/R) |
Checked against the official texts on 2026-11-17. Before relying on a point at work, check the current consolidated text on EUR-Lex and the AMC & GM currently published by EASA, including any later ED Decision.
Application: Electrical safety and role boundaries
3 questions · Retry freely · Separate from your final exam
Choose an action, check its consequence and explore the alternatives. Your practice answers are not saved.
During access, a person steadies against a harness. A wire now has outer damage; the nearby light is off and the circuit state is unknown. The task has been stopped.
- Case
- Illustrative recurrent-training exercise.
- Source
- AMC 20-22 Appendix C Module A.1; AMC 20-21 section 11(k); 145.A.45(a).
Compare all answers and explanations
The lamp is not illuminated; the wire’s energy state remains uncertain. — Best choice.
The indication describes the lamp, not isolation of every relevant energy source.
The lighting supply is isolated; handling the damaged wire can begin. — Consider the consequence.
The circuit may have alternative feeds or faults; the task’s isolation and verification remain necessary.
The return is disconnected; other supplies cannot reach this installation. — Consider the consequence.
The observation does not establish the return connection or the absence of another supply.
Compare all answers and explanations
The insulation surface, with the supports accepted from their last inspection. — Consider the consequence.
The load may also have affected supports and terminations.
The conductor path, with terminations accepted if the light operates later. — Consider the consequence.
Function does not establish that the loaded mechanical features remain sound.
The loaded wires, supports and terminations, including possible hidden damage. — Best choice.
Consider the whole loaded installation; an undamaged-looking surface does not settle its condition.
Compare all answers and explanations
Tell them the lamp is off and the access panel will shortly be closed. — Consider the consequence.
This omits the work and isolation state that must be coordinated before power application.
Tell them the affected circuit, work state and isolation controls still in force. — Best choice.
The receiving team needs the actual safety state and affected work before changing aircraft configuration.
Tell them when the defect was found and when the replacement wire will arrive. — Consider the consequence.
The history and materials plan are useful later, but do not communicate the energisation restriction.
Continue with lesson 2: Current data, instruments and fault-isolation discipline