Event review — Electrical safety and role boundaries

Scope, sources and author

Electrical safety and role boundaries

Objective: Recognise an electrical hazard and preserve safety without unauthorised intervention.

AMC 20-22 Appendix B trace: TG4: rows 1; TG6: rows 1.

A handhold becomes a wiring defect

Training case: A person steadies themselves on a harness while entering a bay. No wire breaks visibly, but a clamp moves and a cable jacket is marked. The useful report describes the location, movement, visible damage and actions taken. “Probably serviceable” adds an unsupported conclusion; a smell or an intermittent indication does not identify the failed component.

An EWIS includes connections, protection and supports as well as wires. A person’s weight can strain insulation, supports and terminations. Use the access platform or handhold intended for people. Keep clear of damaged wiring whose electrical state is uncertain and obtain the prescribed maintenance response.

Everyday example. An appliance with a dark display may still have a live supply.

At a Part-145 line station, a technician takes over the bay work after a colleague reports that using the harness as a handhold moved a clamp. The unit’s blank display gives the same limited evidence as the dark appliance. The handover sheet records removal of external power. The aircraft maintenance manual also identifies a battery supply to the affected circuit, and the record has no entry for it. The technician keeps the bay clear and checks the applicable task with the authorised maintainer. Work near the damaged wiring waits until the required isolation and verification are recorded.

Electric shock: protect the rescuer as well

A cleaner sees a colleague collapse beside exposed electrical equipment. Raise the alarm, call the local emergency response and keep others clear. Obtain safe isolation by personnel able and authorised to perform it; do not touch a person who may still be in contact with electricity. Once the scene is electrically safe, trained responders provide first aid and arrange medical assistance. TG6 staff recognise the emergency and summon help; TG4 personnel apply the aircraft isolation instructions within their duties. This is first-aid awareness, not a rescue or resuscitation procedure.

Before anyone restores power

After a unit change, one team asks for power while another is still working in the bay. Establish who controls energisation, identify the supplies and stored-energy precautions specified by the aircraft task, and reconcile the work and isolation status with every affected team. Batteries, external power and other aircraft supplies must be considered where relevant. Observe the task's warnings, placards and barriers; confirm people, tools and disconnected items are in the required safe condition before the authorised person follows the energisation sequence. A convenient switch position is not a substitute for the specified isolation check.

A tripped protective device may indicate a fault. Further switching follows the aircraft and operator instructions for the circumstances. Repeated resets can feed an unresolved fault; a generic course cannot prescribe a switching sequence for every aircraft or operating condition.

Sources: AMC 20-22 Appendix C, Module A, Safety Practices; AMC 20-21 §11(k); 145.A.47(a), (c) and (d), with GM1 145.A.47(d) on coordination of power configuration. First-aid awareness: MedlinePlus, Electrical injury.

Regulatory basis: what this course includes

This course teaches the sources below as amended up to the act or decision shown. Anything published after it is not part of this edition of the course.

Each source and the amendment, edition or decision this course includes
SourceIncluded up to
AMC 20-22 (EWIS training), Target Groups 3–6AMC-20 Amendment 23 (ED Decision 2022/001/R) (AMC 20-22 unchanged since ED Decision 2008/007/R)

Checked against the official texts on 2026-11-17. Before relying on a point at work, check the current consolidated text on EUR-Lex and the AMC & GM currently published by EASA, including any later ED Decision.

Mid-course quiz Ungraded practice

Electrical safety and role boundaries

3 questions · Retry freely · Separate from your final exam

Choose an action, check its consequence and explore the alternatives. Your practice answers are not saved.

Your scenario · Fictional training example

Hypothetical recurrent-training case: During access, a person grips a harness in the rear bay. A clamp moves and the jacket is marked. The service person stops work and calls maintenance; nobody has yet confirmed isolation.

Included duties
TG3: electrical/avionic engineering on in-service aeroplanes; TG4: general maintenance/inspection outside wire maintenance, including LRU changes; TG5: other engineering and maintenance planning; TG6: service duties near wiring
Application
Recognise an electrical hazard and preserve safety without unauthorised intervention.
Which conclusion follows after a harness moves under a person’s grip but no wire visibly breaks?
Compare all answers and explanations

Support or termination damage may be hidden by the intact outer appearance. — Best choice.
A person’s load can damage supports or terminations without an immediate visible break.

A photograph of the disturbed clamp is sufficient to accept it. — Consider the consequence.
A photograph records the condition; it does not establish serviceability.

The absence of a break limits the assessment to restoring the identification label. — Consider the consequence.
Hidden mechanical damage remains possible. AMC 20-21 §11(k) advises against using bundles as supports.

A protective device has tripped during this work. What governs the next switching action?
Compare all answers and explanations

The earlier reset sequence recorded for a similar indication on another aircraft. — Consider the consequence.
A superficially similar event does not establish the applicable reset instructions.

The completion of a self-test on equipment supplied by an unaffected circuit. — Consider the consequence.
Another circuit’s test does not resolve the tripped circuit’s condition.

The aircraft instructions for this event and the person assigned to apply them. — Best choice.
Use the aircraft-specific safety precautions; re-energising an unresolved fault can worsen it. AMC 20-22, Module A §1.

Which entry best preserves what the service person actually observed?
Compare all answers and explanations

Rear bay: connector failure suspected; replacement requested during the next scheduled input. — Consider the consequence.
The report invents a component diagnosis.

Rear bay: clamp moved during access; jacket marked; work stopped and maintenance called. — Best choice.
This separates observations and action from diagnosis, supporting the response to mechanical damage. AMC 20-22, Module C §5.

Rear bay: jacket marked during access; system operated afterwards, so damage judged superficial. — Consider the consequence.
Operation does not establish the condition of the insulation or supports.

Continue with lesson 2: Event review — LRU replacement without collateral wiring damage

€55 per seat + VAT where applicable

Get the syllabus by email

Not ready to buy? We email you the printable syllabus, the free lesson and the course page.

Continue?

Help & feedback

Get guidancePrepared answers about buying, learning and certificates.

For questions about lesson content, open Ask Metis inside that lesson.

Submitted feedback is stored. If you request a reply, your reply email is stored.