Lesson 1 of 7

Event review — Electrical safety and role boundaries

Learning objective: Recognise an electrical hazard, coordinate safe power changes and explain the response to an electrical injury.

Why this refresher belongs in the competence programme

Regulation (EU) 2018/1139, Articles 15(2) and 17(1), provides the framework for maintenance-organisation approvals and implementing rules. Regulation (EU) No 1321/2014, Annex II (Part-145), 145.A.30(e) requires the organisation to establish and control personnel competence, including human factors appropriate to each person's work. AMC5 145.A.30(e)(a) says the organisation should assess particular training needs; paragraph (b) refers to AMC 20-22 for EWIS training guidance.

AMC 20-22 section 2 explicitly says there is no direct regulatory requirement for EWIS training of Groups 3–8. The employer therefore maps actual duties to the recommended TG4 syllabus and its competence programme. The binding competence requirement and the AMC training model have different status: an implementing rule sets an obligation, AMC describes an acceptable means of compliance, and GM explains the rules.

A harness used as a handhold

During access, a mechanic steadies against a wire bundle. No wire breaks and the connected equipment still operates. That result says little about a strained termination or displaced support. Arrange proper access and report where the load was applied, what moved and what was observed. AMC 20-21 section 11(k) recommends platforms or protective boards and expressly advises against using bundles as handholds, steps or supports.

The electrical wiring interconnection system (EWIS) includes wires, connections, supports and protection, not just visible cable (CS 25.1701). Damage can interrupt a function, connect circuits unintentionally or produce heat and smoke. If smoke, arcing, unusual heat or exposed wiring is seen, keep people clear and initiate the aircraft's emergency or maintenance response. Preserve observations: location, onset, duration, power changes and action taken. These facts help the internal safety investigation under 145.A.202(c)(2); a confident component diagnosis from a smell does not.

Power off, isolated and safe to approach

A switched-off display does not establish the energy state of the wiring beside it. Identify the power sources and isolation points stated in the task, including any alternative supply or stored-energy precautions. Apply the prescribed isolation, identification and warning arrangements, and the task's method of confirming the safe state. Retain those controls against unintended re-energisation. A tripped circuit-protection device also needs the aircraft and operator's procedure for the circumstances; repeated resets can feed an unresolved fault.

Before power is restored for a test, the person controlling the power change coordinates with everyone whose work may be affected. Confirm the work state, people clear, equipment configuration and warning/isolation status required by the task. Someone working elsewhere on the aircraft may still depend on that isolation. This applies AMC 20-22 Appendix C, Module A.1(b)–(d), with current maintenance data under 145.A.45(a).

Everyday example. An appliance is switched off at its controls. That does not establish that every part of its supply is disconnected.

At a Part-145 line station, a transport jet’s display is dark before an avionics unit exchange. The dark display is like the switched-off appliance. The isolation card defines which parts must be made safe. The work pack shows that a neighbouring team has switched off the display for its own task. The mechanic leaves the connector alone until the isolation for this exchange is confirmed by the checks on the applicable card. The display can stay dark in both states.

When a person receives an electric shock

A colleague collapses beside an open electrical panel. Raise the alarm and summon emergency help. Keep others out of the hazard and arrange safe isolation using the emergency procedure. Do not touch the casualty while electrical contact may remain: the rescuer can become a second casualty. Once contact with the source has been safely broken and approach is safe, give first aid within your training and follow emergency-service instructions.

Electrical injury and first aid are selected subjects in AMC 20-22 Appendix C, A.1(a). The first-response principles above are also explained in St John Ambulance's electric-shock guidance. The aircraft emergency procedure supplies the actual isolation actions.

Regulatory basis: what this course includes

This course teaches the sources below as amended up to the act or decision shown. Anything published after it is not part of this edition of the course.

Each source and the amendment, edition or decision this course includes
SourceIncluded up to
AMC 20-22 (EWIS training), Target Group 4AMC-20 Amendment 23 (ED Decision 2022/001/R) (AMC 20-22 unchanged since ED Decision 2008/007/R)

Checked against the official texts on 2026-11-17. Before relying on a point at work, check the current consolidated text on EUR-Lex and the AMC & GM currently published by EASA, including any later ED Decision.

Mid-course quiz Ungraded practice

Event review: Electrical safety and role boundaries

3 questions · Retry freely · Separate from your final exam

Choose an action, check its consequence and explore the alternatives. Your practice answers are not saved.

Your scenario · Fictional training example

During access, a mechanic used a harness as a handhold. No wire broke. A nearby cable has outer damage and its electrical state is unconfirmed. A protection device has also tripped.

Role
General maintenance and inspection staff whose duties exclude wiring maintenance
Task focus
Recognise an electrical hazard, coordinate safe power changes and explain the response to an electrical injury.
Case context
Constructed training scenario; use aircraft-specific data for actual work.
What can be concluded from the harness still looking intact?
Compare all answers and explanations

The applied load may affect hidden terminations, insulation or supports. — Best choice.
Correct. Supports, insulation or terminations can be affected without an immediate visible break; arrange an assessment. AMC 20-21 11(k).

The clamp spacing shows whether it could carry a person safely. — Consider the consequence.
Clamp spacing is for the wiring installation, not personnel support. AMC 20-21 11(k).

The absence of a visible break establishes that the supports held safely. — Consider the consequence.
Appearance does not establish concealed condition or suitability as a handhold. AMC 20-21 11(k).

What should determine the response to the tripped device?
Compare all answers and explanations

Use the reset instruction for a similar unit on the previous aircraft. — Consider the consequence.
A similar unit may have different installation and operating instructions; use this aircraft and operator procedure. AMC 20-22 Appendix C A.1.

Use the last successful reset entry to select the next action. — Consider the consequence.
A past outcome does not resolve the present fault or define the response. AMC 20-22 Appendix C A.1.

Use this aircraft and operator procedure for the symptoms observed. — Best choice.
Correct. Identify the applicable response before re-energising a possible fault. AMC 20-22 Appendix C A.1; 145.A.45(a).

Which report would help the next team assess this event?
Compare all answers and explanations

Record the bay, last satisfactory test and suspected unit to replace. — Consider the consequence.
These details omit the observed sequence and suggest a cause not yet established. 145.A.202(c)(2).

Record the location, symptoms, timing and action already taken. — Best choice.
Correct. These observations help the investigation reconstruct what happened. 145.A.202(c)(2).

Record the bay, recent work and recommended test for the next visit. — Consider the consequence.
Useful context, but it omits the actual symptoms, timing and immediate actions. 145.A.202(c)(2).

Continue with lesson 2: Event review — LRU replacement without collateral wiring damage

€55 per seat + VAT where applicable

Get the syllabus by email

Not ready to buy? We email you the printable syllabus, the free lesson and the course page.

Continue?

Help & feedback

Get guidancePrepared answers about buying, learning and certificates.

For questions about lesson content, open Ask Metis inside that lesson.

Submitted feedback is stored. If you request a reply, your reply email is stored.