Free lesson preview: EWIS Groups 4 & 5 — Recurrent
EWIS — AMC 20-22 — Target Groups 4 & 5 — Recurrent Knowledge Training
Lesson 1 of 10, exactly as learners see it. No sign-in needed; practice answers are not saved.
- 3 hours learning
- 12 questions, 18 min
- Certificate at 75 %
Lesson 1 of 10
Event review — Electrical safety and role boundaries
Scope, sources and author
Electrical safety and role boundaries
Objective: Recognise an electrical hazard and preserve safety without unauthorised intervention.
AMC 20-22 Appendix B trace: TG4: rows 1.
Review the changed condition
A technician steadies a ladder by gripping a wire bundle. No wire appears broken afterwards, but a clamp has moved. The review needs to consider the load on supports and terminations as well as the visible insulation. Use the access platform or other personnel support intended for the job; wiring is not a handhold. This and the other event reviews in this course are illustrative recurrent-training scenarios, not claims about documented local occurrences.
Confirm isolation before approaching the fault
EWIS includes wiring, connections, supports and protection. Damage can interrupt a function, connect circuits unintentionally or create heat and smoke.
Everyday example. A dark appliance display tells you what the display is doing, not whether the supply is isolated.
At a Part-145 line station, a technician is replacing an avionics unit on a passenger jet. Its blank screen is the dark appliance display. The removal card identifies aircraft battery and external power as possible sources. The technician confirms the aircraft and unit, reads the current task’s warnings and isolation instructions, and coordinates with the teams using aircraft power. A blank screen or a single open circuit breaker leaves the status of other feeds and nearby wiring unresolved. The authorised person isolates the listed supplies, applies the prescribed warnings and controls against reconnection, and waits any specified discharge period before verifying the safe state. A qualified person makes any required electrical measurement using the prescribed method and equipment.
When power is needed for a test, establish who controls its application, warn affected personnel and confirm the task’s prerequisites, including clearance of people and equipment from affected systems. Apply power in the specified sequence. After the test, re-establish the prescribed safe state before continuing work. These are applications of AMC 20-22 Appendix C, Module A.1, not a substitute switching sequence for an aircraft.
| Observed condition | Why it matters | Next action |
|---|---|---|
| Split insulation with uncertain energisation | A person could contact an electrical or thermal hazard. | Keep clear; obtain the prescribed isolation and damage assessment. |
| Circuit-protection device has tripped | Further energisation can feed the unresolved fault. | Use the aircraft maintenance and operator instructions for the circumstances; a reset remembered from another task is not the basis. |
| Smoke from a bay; cause unconfirmed | A diagnosis would go beyond the observation. | Report the location, time, symptoms and actions taken, distinguishing observations from suspected causes. |
If someone receives an electric shock
An electric shock can cause burns or cardiac arrest, and serious injury may exist even when a burn is small or not visible. Raise the alarm and summon emergency assistance and trained first aiders immediately. Do not touch the person while they may still be in contact with the supply. Arrange safe isolation through the emergency procedure; do not improvise a rescue that exposes another person. Once the electrical hazard is controlled, trained responders can give first aid. See NHS inform: electric shock first aid.
Sources for this review
AMC 20-22 §2 and Appendix C, Module A.1; AMC 20-21 §11(k), access and personnel loads. For work in a Part-145 organisation, 145.A.45(a) requires applicable current maintenance data.
Regulatory basis: what this course includes
This course teaches the sources below as amended up to the act or decision shown. Anything published after it is not part of this edition of the course.
| Source | Included up to |
|---|---|
| AMC 20-22 (EWIS training), Target Groups 4 & 5 | AMC-20 Amendment 23 (ED Decision 2022/001/R) (AMC 20-22 unchanged since ED Decision 2008/007/R) |
Checked against the official texts on 2026-11-17. Before relying on a point at work, check the current consolidated text on EUR-Lex and the AMC & GM currently published by EASA, including any later ED Decision.
Electrical safety and role boundaries
3 questions · Retry freely · Separate from your final exam
Choose an action, check its consequence and explore the alternatives. Your practice answers are not saved.
Illustrative recurrent-training scenario: An access team used a wire bundle as a handhold. A clamp moved but no wire is visibly broken. Nearby insulation is split and isolation has not been confirmed.
- Included duties
- TG4: general maintenance/inspection outside wire maintenance, including LRU changes; TG5: other engineering and maintenance planning
- Application
- Recognise an electrical hazard and preserve safety without unauthorised intervention.
Compare all answers and explanations
Yes, if a visual check confirms that its outer protection is intact. — Consider the consequence.
Intact outer protection does not make wiring a personnel support. Source: AMC 20-21 §11(k); AMC 20-22 Appendix C, Module A.1.
No. Its wires and supports are not designed for personnel loads. — Best choice.
A person can load the supports and terminations even when no immediate break is visible. Source: AMC 20-21 §11(k); AMC 20-22 Appendix C, Module A.1.
Yes, if the clamp remains rigid during the access manoeuvre. — Consider the consequence.
Apparent rigidity does not establish a personnel-load capability. Source: AMC 20-21 §11(k); AMC 20-22 Appendix C, Module A.1.
Compare all answers and explanations
The aircraft and operator procedure for these circumstances. — Best choice.
The response depends on the aircraft, task and condition; repeated energisation can feed a fault. Source: AMC 20-22 Appendix C, Module A.1; 145.A.45(a).
The procedure from the previous comparable trip. — Consider the consequence.
A comparable event does not establish the applicable switching instructions. Source: AMC 20-22 Appendix C, Module A.1; 145.A.45(a).
The equipment test sequence repeated until clear. — Consider the consequence.
A test sequence does not justify repeated re-energisation of an unresolved fault. Source: AMC 20-22 Appendix C, Module A.1; 145.A.45(a).
Compare all answers and explanations
Location, most recent test result and an estimated cause. — Consider the consequence.
The earlier test result is useful context but cannot replace the present observations. Source: AMC 20-22 Appendix C, Module A.1; 145.A.47(c).
Location, observations, timing and actions already taken. — Best choice.
Report facts and distinguish any suspicion; this supports assessment without inventing a cause. Source: AMC 20-22 Appendix C, Module A.1; 145.A.47(c).
Location, suspected component and the proposed replacement time. — Consider the consequence.
A proposed replacement and diagnosis do not describe the observed damage or current state. Source: AMC 20-22 Appendix C, Module A.1; 145.A.47(c).
Continue with lesson 2: Event review — LRU replacement without collateral wiring damage
€55 per seat + VAT where applicable
Get the syllabus by email
Not ready to buy? We email you the printable syllabus, the free lesson and the course page.