Lesson 1 of 7

Event review — Electrical safety and role boundaries

Learning objective: Recognise electrical hazards, respect power warnings and explain safe assistance and circuit-protection limitations.

Revision 0 · Reviewed 2026-11-23 · Author: Dionysis Kefalas. This refresher assumes previous appropriate initial training for flight deck duties. Electrical Wiring Interconnection System (EWIS) means the installed network carrying electrical power, data and signals between termination points. It includes wires, connectors, splices, bonding connections, supports and protection. For example, a sensor signal reaches a cockpit display through wiring and connectors; the clamps keep that wiring away from damaging movement. CS 25.1701 supplies the definition for large-aeroplane certification; it is not a pilot qualification rule.

EWIS is wiring, connections, supports and protectionA labelled side elevation shows individually insulated wires entering and leaving a supported metal conduit, continuing through a rubber grommet in a frame-web opening, and held by a cushioned clamp on a bolted bracket before entering a mated connector on mounted equipment. A separate insulated bond lead connects an equipment stud to a ring terminal and structural bond stud. Enlarged Detail A shows the grommet groove seated over the cut hole edge; enlarged Detail B shows the clamp from the cable end, with metal band, elastomer cushion and fixing bolt.EWIS is wiring, connections, supports and protectionRepresentative installation with local sections · not to scale Detail A · grommet ×3Frame webElastomergrommetDetail B · support clamp ×3Metal bandElastomer cushionExposed at cutawayFixing boltABInsulated bundleConduitConnectorEquipmentGround or bond pointBond leadSurrounding structure
Figure 1.1. A continuous bundle passes through supported conduit and a grommeted frame opening, then through a cushioned clamp to a mated connector. A separate bond lead ends in a lug secured to structure; actual installation and assessment require the applicable aircraft data.

A turnaround warning overlooked

During a crew walk-round, a pilot sees a ground worker steady themself on a bundle beside an open access area. The bundle springs back; no break is visible. A maintenance power warning remains displayed, but the flight-deck screens are dark. Departure is approaching and someone suggests completing the power-up to see whether anything has failed.

The pilot asks the worker to stop using the bundle, alerts the commander and maintenance, and reports the exact location and loading event. The visible return to position is a fact; undamaged supports and terminations are not established. The maintenance warning remains effective until the responsible personnel clear it through the agreed coordination process. A power-up is not an improvised damage test.

Electrical safety and safe assistance

Current can cause fatal shock and burns. Dark equipment does not establish isolation: aircraft electrical systems can have more than one supply (see CS 25.1351(b), (d)). Respect maintenance warnings and coordinate power application with the personnel controlling the work. Do not touch, probe, disconnect or move suspect wiring during a crew observation. Never use bundles as handholds or supports; the load can strain insulation, clamps and terminations even when equipment still works. AMC 20-22 Appendix C A1 covers power application, isolation, warnings, first aid and human factors; AMC 20-21 section 11(k) explains access precautions.

If a person may still be in electrical contact, keep yourself and others clear, summon emergency help and initiate the applicable safe-isolation response. Do not touch the casualty until the electrical danger has been made safe. Then use your trained first-aid response and obtain medical assistance. This follows the scene-safety principle in NHS first-aid guidance, electric shock; aircraft isolation must follow aircraft instructions.

Everyday example. An appliance that looks switched off is not proof that its exposed connections are safe.

On a regional aircraft turnaround, a pilot has reported a ground worker leaning on a wire bundle. The flight-deck screens are dark. A maintenance power warning remains in place. Like an appliance that looks switched off, the dark screens leave the state of the wiring unknown. The commander asks the engineer responsible for the warning whether the loading event has been assessed and what power changes, if any, the crew may make. Departure pressure and a familiar power-up sequence make this check easy to skip. Keep the warning in force until the agreed handover.

CAP 715, chapter 1 section 3.1 and chapter 4 section 3, discuss complacency and time pressure in maintenance.

What circuit protection tells you

A circuit breaker opens a circuit at a predetermined current overload. Some arcing faults may not be disconnected sufficiently quickly, so an untripped breaker does not rule out an electrical hazard. Opening the circuit interrupts power; it does not restore damaged insulation or remove contamination. Reapplying power may restart damage even if the equipment initially works. Use the aircraft/operator instructions for the actual circumstances; Lesson 4 explains emergency authority.

Safety guidance: FAA AC 120-80B sections 7.4 and 17.1–17.3 explain circuit protection and its limitations. EASA SIB 2009-07, issued 2009-03-27, warns about resetting tripped breakers and is expressly non-mandatory information. Neither document supplies a generic reset permission.

Regulatory basis: what this course includes

This course teaches the sources below as amended up to the act or decision shown. Anything published after it is not part of this edition of the course.

Each source and the amendment, edition or decision this course includes
SourceIncluded up to
AMC 20-22 (EWIS training), Target Group 7AMC-20 Amendment 23 (ED Decision 2022/001/R) (AMC 20-22 unchanged since ED Decision 2008/007/R)

Checked against the official texts on 2026-11-17. Before relying on a point at work, check the current consolidated text on EUR-Lex and the AMC & GM currently published by EASA, including any later ED Decision.

Mid-course quiz Ungraded practice

Event review: Electrical safety and role boundaries

3 questions · Retry freely · Separate from your final exam

Choose an action, check its consequence and explore the alternatives. Your practice answers are not saved.

Your scenario · Fictional training example

During a crew walk-round, a worker uses a bundle beside an open access area as a handhold. It springs back with no visible break. A maintenance power warning remains displayed; flight-deck screens are dark and departure is approaching.

Your role
Flight deck crew
Known facts
Use the observations stated in the case; explain what remains uncertain.
Why does the brief handhold event need attention even though the bundle returned to position?
Compare all answers and explanations

The load may have strained supports or terminations beyond what is visible. — Best choice.
A normal appearance does not establish undamaged supports or connections. Report the loading event and location: AMC 20-21 section 11(k).

The load is acceptable if the crew can confirm normal equipment operation afterwards. — Consider the consequence.
Electrical function does not demonstrate that mechanical damage has been avoided. The bundle is not an access support.

The load is acceptable when several clamps distribute it along the bundle. — Consider the consequence.
The clamps support the wiring installation; sharing a person’s weight does not establish their suitability for that load.

What should happen before the proposed routine power-up?
Compare all answers and explanations

Complete the usual cockpit power-up while ground staff watch the affected bundle. — Consider the consequence.
Observation during energisation is not a substitute for resolving the warning and damage concern.

Use the normal power-up sequence once the worker has stepped clear of the opening. — Consider the consequence.
Moving a person away does not establish that the maintenance work permits power application.

Coordinate with maintenance over the warning and the reported loading event. — Best choice.
Power application, warnings and isolation belong together: AMC 20-22 Appendix C A1. The crew need an agreed status before proceeding.

Which statement correctly interprets the dark flight-deck screens?
Compare all answers and explanations

They establish that nearby exposed wiring is isolated from aircraft supplies. — Consider the consequence.
An inactive display is not an isolation check of nearby circuits.

They show display inactivity, while the electrical state of nearby wiring remains unconfirmed. — Best choice.
Another supply may remain available. Respect the warning and aircraft isolation arrangements: AMC 20-22 Appendix C A1.

They establish isolation once external power has been removed from the aircraft. — Consider the consequence.
External power is not necessarily the only supply. Use the aircraft’s specified isolation arrangements.

Continue with lesson 2: Event review — Recognising abnormal wiring conditions

€19 per seat + VAT where applicable

Get the syllabus by email

Not ready to buy? We email you the printable syllabus, the free lesson and the course page.

Continue?

Help & feedback

Get guidancePrepared answers about buying, learning and certificates.

For questions about lesson content, open Ask Metis inside that lesson.

Submitted feedback is stored. If you request a reply, your reply email is stored.