Electrical safety and role boundaries
Learning objective: Recognise an electrical hazard and preserve safety without unauthorised intervention.
What EWIS includes
EWIS means Electrical Wiring Interconnection System: installed wiring and associated devices carrying electrical power, data and signals between intended termination points. The installation includes connections, insulation, protective sleeving, clamps, identification and bonding or grounding connections. A wire carries the supply or signal; a connector joins intended circuits; a clamp supports the run so movement does not load the connection. These are parts of a system, not spare handholds.
CS 25.1701(a)–(c) gives the certification definition for large aeroplanes and its exclusions. Portable devices outside the type design are among those exclusions. A personal charging lead can nevertheless snag controls or disturb installed wiring. Its potential to harm the aircraft matters even though it is not thereby part of aircraft EWIS.
Energy uncertainty within crew duties
Everyday example. A lamp that has gone dark at home tells you only that the lamp is dark. The socket could still be live.
During an airline turnaround, the first officer finds a dark display on the centre instrument panel and a maintenance warning against applying power. Like the dark lamp, the blank display gives no evidence of isolation. Another supply or stored energy may still be present, even with the function deselected. The first officer checks the warning and asks the engineer controlling the work to confirm when the crew may change the power configuration. Until that handover, the crew leave the switches as they are and keep clear of the work area.
Keep hands and equipment away from exposed or damaged wiring. Do not use a bundle to steady yourself or hang a work light from it: the load can reach hidden supports and terminations. AMC 20-21 section 11(k) recommends avoiding such loading. Electrical safety training under AMC 20-22 Appendix C, Module A, section 1 includes applying power, isolation, warnings, first aid and human factors.
If someone receives an electric shock
Electricity can cause fatal injury. Do not touch a person who is still in contact with the electrical source: you could become a second casualty. Summon emergency assistance and arrange safe isolation through the aircraft or ground emergency procedure. Once electrical contact has ended and it is safe to approach, provide first aid within your training and obtain urgent medical assistance. Use the first-aid training and emergency arrangements for your workplace; do not improvise contact with exposed conductors. Sources: AMC 20-22 Appendix C, Module A, section 1(a); NHS inform, Electric shock first aid.
Worked situation
During departure preparation, maintenance is still testing equipment behind an open panel. A warning identifies testing in progress, and a colleague asks you to restore power because the displays are dark. Confirm test status and the permitted configuration with the responsible team before switching. Respect the warnings until that team has completed the required coordination. If a person is receiving a shock, call for emergency help and safe isolation; reaching into the panel to pull the person away may expose you too.
Departure pressure, familiarity and an interrupted conversation can turn “the screen is off” into an unsafe assumption. State the unresolved issue, identify who controls the test, and agree who may change power. If interrupted, resume by re-establishing the last confirmed configuration rather than relying on memory. This is the practical human-factors part of electrical safety, not an extra technical test. Sources: AMC 20-22 Appendix C, Module A, section 1(b)–(e); CAP 715, Chapter 4, section 3 (time pressure) and Chapter 8 (human error).
Regulatory basis: what this course includes
This course teaches the sources below as amended up to the act or decision shown. Anything published after it is not part of this edition of the course.
| Source | Included up to |
|---|---|
| AMC 20-22 (EWIS training), Target Group 7 | AMC-20 Amendment 23 (ED Decision 2022/001/R) (AMC 20-22 unchanged since ED Decision 2008/007/R) |
Checked against the official texts on 2026-11-17. Before relying on a point at work, check the current consolidated text on EUR-Lex and the AMC & GM currently published by EASA, including any later ED Decision.
Application: Electrical safety and role boundaries
3 questions · Retry freely · Separate from your final exam
Choose an action, check its consequence and explore the alternatives. Your practice answers are not saved.
During preparation, a pilot sees damaged covering at an open access edge. The adjacent display is dark. Maintenance is still testing the installation and a test warning remains displayed.
- Crew task
- Recognise an electrical hazard and preserve safety without unauthorised intervention.
- Exercise
- Use the stated observations; do not assume a fault source or aircraft-specific switching sequence.
Compare all answers and explanations
The display is dark; the damaged circuit’s isolation state is still unknown. — Best choice.
An inactive indication cannot establish isolation of all relevant sources. Source: AMC 20-22 Appendix C, Module A, section 1(b)–(d).
The supply is isolated; the dark display confirms the test area is safe. — Consider the consequence.
A display state is not confirmation that the test team has isolated every relevant supply. Source: AMC 20-22 Appendix C, Module A, section 1(b)–(d).
The circuit is discharged; the dark display confirms its stored energy has gone. — Consider the consequence.
A dark display cannot show that energy has been discharged from the damaged circuit. Source: AMC 20-22 Appendix C, Module A, section 1(b)–(d).
Compare all answers and explanations
A short grip is acceptable if the visible cable position stays unchanged. — Consider the consequence.
Visible position does not establish the condition of hidden attachments. Source: AMC 20-21 section 11(k).
A shared grip spreads the load so that each wire remains within its rating. — Consider the consequence.
Wire ratings do not make a bundle a personnel support. Source: AMC 20-21 section 11(k).
A handhold load can damage insulation and reach concealed supports or terminations. — Best choice.
Guidance recommends avoiding wire bundles as handholds, steps or supports. Source: AMC 20-21 section 11(k).
Compare all answers and explanations
Restore the normal configuration once the cockpit displays are confirmed dark. — Consider the consequence.
Dark displays do not establish the test state or permission to energise. Source: AMC 20-22 Appendix C, Module A, section 1(b)–(e).
Confirm test status with the responsible team and agree the configuration before switching. — Best choice.
Test warnings and isolation arrangements need coordination before power changes. Source: AMC 20-22 Appendix C, Module A, section 1(b)–(e).
Restore the normal configuration while another crew member watches the opening. — Consider the consequence.
Watching an opening does not establish what is connected or safe to energise. Source: AMC 20-22 Appendix C, Module A, section 1(b)–(e).
Continue with lesson 2: Recognising abnormal wiring conditions