Free lesson preview: EWIS Groups 7 & 8 — Recurrent
EWIS — AMC 20-22 — Target Groups 7 & 8 — Recurrent Knowledge Training
Lesson 1 of 8, exactly as learners see it. No sign-in needed; practice answers are not saved.
- 2.5 hours learning
- 12 questions, 18 min
- Certificate at 75 %
Lesson 1 of 8
Event review — Electrical safety and role boundaries
Scope, sources and author
Electrical safety and role boundaries
Objective: Recognise an electrical hazard and preserve safety without unauthorised intervention.
AMC 20-22 Appendix B trace: TG7: rows 1; TG8: rows 1.
Review the changed condition
Illustrative recurrent-training scenario. During boarding, a crew member sees a colleague grip a bundle beside an open service panel. The colleague lets go; no warning appears. A passenger then asks for a failed outlet to be restored quickly. The review question is whether the apparently normal system justifies closing the concern.
What belongs to the wiring system?
Electrical Wiring Interconnection System (EWIS) means the installed wiring and associated devices that transmit electrical energy, including data and signals, between intended termination points. It includes connections, insulation, supports, clamps and electrical bonding and grounding devices. A power cable under a seat, its connector and its supports are a useful cabin example. The CS 25.1701 definition excludes portable devices outside the aircraft type design and specified equipment internals; it does not make every electrical item EWIS.
Insulation separates conductors from other conductors and structure. Supports keep wiring in its intended position. Loading a bundle with a person's weight can damage either, or strain a termination, even when equipment continues to work. AMC 20-21 section 11(k), gaining access, advises against using bundles as handholds, steps or supports.
Electrical shock, power and help
Suspect an electrical injury when someone reports a shock or collapses after contact with electrical equipment. Electricity can kill. Do not touch a person who may still be in contact with the supply: you could become a second casualty. Keep others clear, summon assistance immediately and obtain the prescribed power-isolation response. Once the electrical danger has been removed, use the operator's trained first-aid arrangements, including resuscitation and medical assistance as appropriate. This review supports, rather than replaces, that practical training.
An equipment switch at OFF is not evidence that its supply wiring is isolated. The aircraft can have more than one power source, and some equipment stores energy. Respect warnings, isolation notices and instructions from the responsible personnel before any change of power.
Everyday example. Switch off a bedside lamp and the lamp goes dark, but the cable to its switch may still be live.
At the gate on a passenger jet, a cabin crew member reports an electrical shock beside a galley unit with a blank display. Like the dark lamp, the blank display only tells the crew that the equipment is dark. The senior cabin crew member keeps people clear, calls for medical help and coordinates isolation with the flight deck and ground team under the aircraft procedure. Never touch the equipment to test it. Crew keep clear of the equipment and the casualty until that procedure confirms the electrical danger has been removed. They then give first aid as trained. Use the lamp comparison to recognise that power may still be present. Use the aircraft procedure to confirm isolation.
Pressure to restore a service
Everyday example. After a night shift, even a familiar drive home needs your attention. If you are tired, arrange another way home.
During boarding on the last sector of an overnight duty, a passenger asks for the outlet to be restored. A cabin crew member is already reporting that a colleague gripped the wiring bundle beside an open service panel. The familiar outlet is the familiar road home: at the end of an overnight duty it invites a routine answer, so the crew member keeps checking what is actually in front of them. They keep people clear of the open panel and finish passing its location and what happened for the cabin defect report. They ask a colleague to tell the passenger that the outlet will stay out of use while the crew follow the operator's defect procedure. Familiarity with the outlet gives no evidence about the bundle's condition.
This is crew resource management (CRM) in practice: manage fatigue, stay alert, share the workload and keep safety information moving.
Sources for this review
CS 25.1701(a)–(c); AMC 20-21 section 11(k), gaining access; AMC 20-22 Appendix C, Module A, Safety Practices 1(a)–(e); AMC1 ORO.CC.115(e), Table 1; NHS 111 Wales: first aid, electric shock and resuscitation.
Regulatory basis: what this course includes
This course teaches the sources below as amended up to the act or decision shown. Anything published after it is not part of this edition of the course.
| Source | Included up to |
|---|---|
| AMC 20-22 (EWIS training), Target Groups 7 & 8 | AMC-20 Amendment 23 (ED Decision 2022/001/R) (AMC 20-22 unchanged since ED Decision 2008/007/R) |
Checked against the official texts on 2026-11-17. Before relying on a point at work, check the current consolidated text on EUR-Lex and the AMC & GM currently published by EASA, including any later ED Decision.
Electrical safety and role boundaries
3 questions · Retry freely · Separate from your final exam
Choose an action, check its consequence and explore the alternatives. Your practice answers are not saved.
Illustrative review: During boarding a colleague grips a wire bundle beside an open panel, then lets go. No warning appears. A passenger asks for an outlet to be restored. The bundle has outer damage and its electrical state is unknown.
- Review focus
- Electrical safety and role boundaries
Compare all answers and explanations
A person can damage supports, insulation or connections. — Best choice.
The load can damage the installation even while equipment still works. AMC 20-21 section 11(k), gaining access.
A brief grip is safe if the support stays in position. — Consider the consequence.
Position afterwards does not reveal strain or concealed damage. AMC 20-21 advises against using bundles as supports.
Several clamps make this a suitable access support. — Consider the consequence.
Bundle size does not make wiring a personnel support. Use the proper access arrangements.
Compare all answers and explanations
Move the colleague clear by gripping their nearest exposed arm. — Consider the consequence.
Touching a person still in electrical contact can make you a second casualty. Summon help and obtain safe isolation.
Test the cable jacket by touch before asking for power isolation. — Consider the consequence.
A touch test exposes you to the same hazard and cannot establish isolation.
Keep clear, call for help and obtain the prescribed isolation response. — Best choice.
Protect against a second casualty; once the electrical danger is removed use trained first-aid arrangements. AMC 20-22 Appendix C, Module A 1(a); NHS 111 Wales, First aid, electric shock.
Compare all answers and explanations
Finish the service request; report if a warning develops. — Consider the consequence.
A normal indication does not dispose of the observed damage. Service pressure must not suppress the report.
Finish the hazard message and share the passenger task with a colleague. — Best choice.
This preserves the observation while managing workload. AMC1 ORO.CC.115(e), Table 1 covers workload, vigilance and communication.
Ask the experienced colleague to decide whether the grip needs reporting. — Consider the consequence.
Experience does not establish the condition of the installation; communicate what happened.
Continue with lesson 2: Event review — Recognising abnormal wiring conditions
€39 per seat + VAT where applicable
Get the syllabus by email
Not ready to buy? We email you the printable syllabus, the free lesson and the course page.