EWIS Groups 7 & 8 — Initial

Free lesson preview: EWIS Groups 7 & 8 — Initial

EWIS — AMC 20-22 — Target Groups 7 & 8 — Initial Knowledge Training

Lesson 1 of 8, exactly as learners see it. No sign-in needed; practice answers are not saved.

  • 2.5 hours learning
  • 12 questions, 18 min
  • Certificate at 75 %

Lesson 1 of 8

Electrical safety and role boundaries

Scope, sources and author

Objective: Recognise an electrical hazard and preserve safety without unauthorised intervention.

AMC 20-22 Appendix B trace: TG7: row 1; TG8: row 1.

Electrical Wiring Interconnection System (EWIS) means the wiring installation and its associated interconnections, including connectors, terminations, supports and protection. Insulation separates conductors from people, structure and other circuits. Clamps support a run; connector contacts and terminals join conductors. Damage can interrupt a function, create an unintended electrical path or produce heat and smoke.

EWIS is wiring, connections, supports and protectionA labelled side elevation shows individually insulated wires entering and leaving a supported metal conduit, continuing through a rubber grommet in a frame-web opening, and held by a cushioned clamp on a bolted bracket before entering a mated connector on mounted equipment. A separate insulated bond lead connects an equipment stud to a ring terminal and structural bond stud. Enlarged Detail A shows the grommet groove seated over the cut hole edge; enlarged Detail B shows the clamp from the cable end, with metal band, elastomer cushion and fixing bolt.EWIS is wiring, connections, supports and protectionRepresentative installation with local sections · not to scale Detail A · grommet ×3Frame webElastomergrommetDetail B · support clamp ×3Metal bandElastomer cushionExposed at cutawayFixing boltABInsulated bundleConduitConnectorEquipmentGround or bond pointBond leadSurrounding structure
Figure 1.1. A continuous bundle passes through supported conduit and a grommeted frame opening, then through a cushioned clamp to a mated connector. A separate bond lead ends in a lug secured to structure; actual installation and assessment require the applicable aircraft data.

Power off is not the same as isolation

Energised means electrically live. Isolation means separating the circuit from its electrical supply sources using the specified process. Aircraft can have several sources, including ground power and batteries. Use the specified aircraft procedure to confirm isolation even after the equipment has been switched off.

Everyday example. A dark household lamp may still have live wires. Even with its switch off, the wiring that supplies the switch can remain live.

During a pre-boarding cabin check on a passenger jet, a cabin crew member notices split insulation at an open reading-light fitting. The dark reading light is the dark household lamp. The wiring behind it could still be live. The crew member keeps others clear, reports the seat and visible damage through the operator's cabin defect procedure and leaves the circuit to maintenance.

A circuit breaker is a protective device designed to open a circuit at a predetermined overload. A trip can signal a fault; resetting may feed that fault again. Some damaging electrical faults may not trip a breaker promptly. Use the aircraft/operator instructions for the actual circumstances, including their warnings and limits; never infer a reset permission from this course. Respect warning placards and isolation notices. Applying aircraft power can energise equipment where another person is working, so power application needs the coordination specified by the operator.

Protect the person as well as the aircraft

Electric current through the body can cause fatal shock; electrical faults can also cause burns. Do not touch a casualty who is still in contact with an electrical source. Raise the alarm and summon emergency assistance. Have the supply made safe through the prescribed aircraft response; avoid improvising contact with the person or wiring. Once access is safe, use the first-aid response for which you are trained and obtain medical assistance.

During a turnaround, a crew member sees damaged wiring at an open equipment area. The service light is off and departure is approaching. The useful action is to keep people clear, alert the responsible team and describe the damage. Testing for heat by hand would expose the crew member to the hazard. Time pressure is a reason to stop the shortcut, not a reason to guess at isolation. Similarly, use the proper access support rather than a bundle: a hand load can strain insulation, clamps and connections even with power isolated.

Sources: CS 25.1701(a)–(c); AMC 20-22 Appendix C, Module A, item 1; AMC 20-21 §11(k); FAA AC 120-80B §§17.1–17.3 (comparative safety guidance); HSE electrical injuries and Electrical Safety First, first aid.

Regulatory basis: what this course includes

This course teaches the sources below as amended up to the act or decision shown. Anything published after it is not part of this edition of the course.

Each source and the amendment, edition or decision this course includes
SourceIncluded up to
AMC 20-22 (EWIS training), Target Groups 7 & 8AMC-20 Amendment 23 (ED Decision 2022/001/R) (AMC 20-22 unchanged since ED Decision 2008/007/R)

Checked against the official texts on 2026-11-17. Before relying on a point at work, check the current consolidated text on EUR-Lex and the AMC & GM currently published by EASA, including any later ED Decision.

Mid-course quiz Ungraded practice

Electrical safety and role boundaries

3 questions · Retry freely · Separate from your final exam

Choose an action, check its consequence and explore the alternatives. Your practice answers are not saved.

Your scenario · Fictional training example

An open access area contains wiring beside a service task. One cable has visible outer damage, but nobody knows whether the circuit is energised.

Included duties
TG7: flight deck crew; TG8: cabin crew
Application
Recognise an electrical hazard and preserve safety without unauthorised intervention.
What is the appropriate first response to the damaged cable?
Compare all answers and explanations

Ask a colleague to hold the cable while the access area is cleared. — Consider the consequence.
Holding the damaged cable exposes the helper to the same hazard.

Keep people clear, report the cable’s location and use the aircraft’s safety response. — Best choice.
Unknown energisation makes exploratory handling unsafe. AMC 20-22 Appendix C, Module A item 1.

Use the service light’s off position to establish circuit isolation. — Consider the consequence.
An inactive load does not establish isolation of its supply wiring.

Which statement explains why the bundle must not support a person?
Compare all answers and explanations

An isolated bundle can take a brief hand load during access. — Consider the consequence.
Isolation addresses electrical supply, not mechanical loading.

A rigid clamp transfers a person’s load safely past the cable. — Consider the consequence.
Clamps support the installation; rigidity does not make them personnel supports.

A person’s hand load can strain wiring and its attachments. — Best choice.
Use proper access support. AMC 20-21 §11(k) advises avoiding bundles as handholds, steps or supports.

Which instructions govern a tripped circuit breaker in flight?
Compare all answers and explanations

The operator’s instructions for this aircraft and event. — Best choice.
Use the actual circumstances and operator policy. AMC 20-22 Appendix C, Module A item 1; FAA AC 120-80B §17.1.

The last aircraft’s reset procedure for equipment of this function. — Consider the consequence.
A similar function does not establish the same architecture or operating conditions.

The ground-service reset procedure whenever no smoke is visible. — Consider the consequence.
Ground and in-flight conditions can differ; absence of smoke gives no reset permission.

Continue with lesson 2: Recognising abnormal wiring conditions

€39 per seat + VAT where applicable

Get the syllabus by email

Not ready to buy? We email you the printable syllabus, the free lesson and the course page.

Continue?

Help & feedback

Get guidancePrepared answers about buying, learning and certificates.

For questions about lesson content, open Ask Metis inside that lesson.

Submitted feedback is stored. If you request a reply, your reply email is stored.