Electrical safety and role boundaries
Scope, sources and author
Objective: Recognise an electrical hazard and preserve safety without unauthorised intervention.
AMC 20-22 Appendix B trace: TG7: row 1; TG8: row 1.
Electrical Wiring Interconnection System (EWIS) means the wiring installation and its associated interconnections, including connectors, terminations, supports and protection. Insulation separates conductors from people, structure and other circuits. Clamps support a run; connector contacts and terminals join conductors. Damage can interrupt a function, create an unintended electrical path or produce heat and smoke.
Power off is not the same as isolation
Energised means electrically live. Isolation means separating the circuit from its electrical supply sources using the specified process. Aircraft can have several sources, including ground power and batteries. Use the specified aircraft procedure to confirm isolation even after the equipment has been switched off.
Everyday example. A dark household lamp may still have live wires. Even with its switch off, the wiring that supplies the switch can remain live.
During a pre-boarding cabin check on a passenger jet, a cabin crew member notices split insulation at an open reading-light fitting. The dark reading light is the dark household lamp. The wiring behind it could still be live. The crew member keeps others clear, reports the seat and visible damage through the operator's cabin defect procedure and leaves the circuit to maintenance.
A circuit breaker is a protective device designed to open a circuit at a predetermined overload. A trip can signal a fault; resetting may feed that fault again. Some damaging electrical faults may not trip a breaker promptly. Use the aircraft/operator instructions for the actual circumstances, including their warnings and limits; never infer a reset permission from this course. Respect warning placards and isolation notices. Applying aircraft power can energise equipment where another person is working, so power application needs the coordination specified by the operator.
Protect the person as well as the aircraft
Electric current through the body can cause fatal shock; electrical faults can also cause burns. Do not touch a casualty who is still in contact with an electrical source. Raise the alarm and summon emergency assistance. Have the supply made safe through the prescribed aircraft response; avoid improvising contact with the person or wiring. Once access is safe, use the first-aid response for which you are trained and obtain medical assistance.
During a turnaround, a crew member sees damaged wiring at an open equipment area. The service light is off and departure is approaching. The useful action is to keep people clear, alert the responsible team and describe the damage. Testing for heat by hand would expose the crew member to the hazard. Time pressure is a reason to stop the shortcut, not a reason to guess at isolation. Similarly, use the proper access support rather than a bundle: a hand load can strain insulation, clamps and connections even with power isolated.
Sources: CS 25.1701(a)–(c); AMC 20-22 Appendix C, Module A, item 1; AMC 20-21 §11(k); FAA AC 120-80B §§17.1–17.3 (comparative safety guidance); HSE electrical injuries and Electrical Safety First, first aid.
Regulatory basis: what this course includes
This course teaches the sources below as amended up to the act or decision shown. Anything published after it is not part of this edition of the course.
| Source | Included up to |
|---|---|
| AMC 20-22 (EWIS training), Target Groups 7 & 8 | AMC-20 Amendment 23 (ED Decision 2022/001/R) (AMC 20-22 unchanged since ED Decision 2008/007/R) |
Checked against the official texts on 2026-11-17. Before relying on a point at work, check the current consolidated text on EUR-Lex and the AMC & GM currently published by EASA, including any later ED Decision.
Electrical safety and role boundaries
3 questions · Retry freely · Separate from your final exam
Choose an action, check its consequence and explore the alternatives. Your practice answers are not saved.
An open access area contains wiring beside a service task. One cable has visible outer damage, but nobody knows whether the circuit is energised.
- Included duties
- TG7: flight deck crew; TG8: cabin crew
- Application
- Recognise an electrical hazard and preserve safety without unauthorised intervention.
Compare all answers and explanations
Ask a colleague to hold the cable while the access area is cleared. — Consider the consequence.
Holding the damaged cable exposes the helper to the same hazard.
Keep people clear, report the cable’s location and use the aircraft’s safety response. — Best choice.
Unknown energisation makes exploratory handling unsafe. AMC 20-22 Appendix C, Module A item 1.
Use the service light’s off position to establish circuit isolation. — Consider the consequence.
An inactive load does not establish isolation of its supply wiring.
Compare all answers and explanations
An isolated bundle can take a brief hand load during access. — Consider the consequence.
Isolation addresses electrical supply, not mechanical loading.
A rigid clamp transfers a person’s load safely past the cable. — Consider the consequence.
Clamps support the installation; rigidity does not make them personnel supports.
A person’s hand load can strain wiring and its attachments. — Best choice.
Use proper access support. AMC 20-21 §11(k) advises avoiding bundles as handholds, steps or supports.
Compare all answers and explanations
The operator’s instructions for this aircraft and event. — Best choice.
Use the actual circumstances and operator policy. AMC 20-22 Appendix C, Module A item 1; FAA AC 120-80B §17.1.
The last aircraft’s reset procedure for equipment of this function. — Consider the consequence.
A similar function does not establish the same architecture or operating conditions.
The ground-service reset procedure whenever no smoke is visible. — Consider the consequence.
Ground and in-flight conditions can differ; absence of smoke gives no reset permission.
Continue with lesson 2: Recognising abnormal wiring conditions