EWIS — AMC 20-22 — Target Group 8 — Initial Knowledge Training

Lesson 1 of 7, exactly as learners see it. No sign-in needed; practice answers are not saved.

  • 2.5 hours learning
  • 12 questions, 18 min
  • Certificate at 75 %

Lesson 1 of 7

Electrical safety and role boundaries

Learning objective: Recognise an electrical hazard and preserve safety without unauthorised intervention.

EWIS means electrical wiring interconnection system: the aircraft’s wiring and associated connections, protection and supports. It carries electrical power, data and signals. CS 25.1701(a) includes connectors, splices, grounding and bonding connections, protective coverings and clamps. This explains why damage to a support or connection matters as well as damage to the cable itself. A portable passenger device is excluded from that EWIS definition by CS 25.1701(c)(2), but can present a separate electrical hazard.

EWIS is wiring, connections, supports and protectionA labelled side elevation shows individually insulated wires entering and leaving a supported metal conduit, continuing through a rubber grommet in a frame-web opening, and held by a cushioned clamp on a bolted bracket before entering a mated connector on mounted equipment. A separate insulated bond lead connects an equipment stud to a ring terminal and structural bond stud. Enlarged Detail A shows the grommet groove seated over the cut hole edge; enlarged Detail B shows the clamp from the cable end, with metal band, elastomer cushion and fixing bolt.EWIS is wiring, connections, supports and protectionRepresentative installation with local sections · not to scale Detail A · grommet ×3Frame webElastomergrommetDetail B · support clamp ×3Metal bandElastomer cushionExposed at cutawayFixing boltABInsulated bundleConduitConnectorEquipmentGround or bond pointBond leadSurrounding structure
Figure 1.1. A continuous bundle passes through supported conduit and a grommeted frame opening, then through a cushioned clamp to a mated connector. A separate bond lead ends in a lug secured to structure; actual installation and assessment require the applicable aircraft data.

For EU commercial air transport, the legal chain starts with Regulation (EU) 2018/1139, Article 29 and Annex V, including the operations manual requirement in point 8.2. Regulation (EU) No 965/2012, CAT.GEN.MPA.100(a), makes each crew member responsible for the proper execution of safety duties specified in that manual. AMC 20-22 supplies the EWIS training model; the operator’s instructions tell crew how to act on their aircraft. Maintenance, where required, follows its own requirements, including Part-145 145.A.45(a) for applicable current maintenance data.

Damage can interrupt a needed function, connect circuits unintentionally or create heat and smoke. Never use a wire bundle as a handhold or support for equipment. The load can reach clamps and connections beyond the visible run, even if the bundle springs back afterwards. AMC 20-21 section 11(k) specifically advises against using wiring as handholds, steps or supports, or hanging work lights from it.

Electrical safety during normal cabin duties

Everyday example. Switching a television to standby still leaves an electrical supply connected.

During boarding on a passenger jet, a cabin crew member sees damaged trim beside the reading light at 12A. The passenger switches the light off. Like the television on standby, it can go dark while its installation remains supplied. A silent seat motor tells you just as little about isolation. The crew member keeps people clear of the suspect wiring, reports the location and condition in the cabin defect log as directed, and follows the operator’s electrical safety procedure. The responsible personnel establish safe isolation before any authorised handling.

Electric current can cause fatal injury and burns. If a passenger appears to receive a shock and remains in contact with a damaged seat fitting, direct contact may make the rescuer another casualty. Initiate the trained electrical-injury response: summon assistance, communicate the suspected live contact and follow the operator’s arrangements for making the situation safe and providing first aid. Do not touch the person or fitting while possible live contact persists. Electrical Safety First’s first-aid guidance, steps 2 and 5, explains the rescuer hazard and the need to stay within first-aid training. AMC 20-22 Appendix C, Module A1(a) and (c), includes electrical first aid and circuit isolation; the aircraft’s isolation actions and first-aid techniques must be learnt in the operator’s training.

Observe warning labels, placards and instructions before equipment use or restoration of power. A warning or an outstanding restriction must be resolved through the responsible crew or maintenance team. Do not remove a warning or restore use to see whether a fault returns. Repeated circuit-breaker resets can feed an unresolved fault. Use the aircraft and operator procedure for the circumstances, rather than a reset remembered from another aircraft. FAA AC 120-80B section 17 explains the reset hazard; it is comparative safety guidance, not an additional EU operating rule.

Boarding example: a trim edge is displaced beside a service unit. Boarding is late and the unit still works. Report the location and visible condition; do not push the wiring behind the trim to tidy it. A request to hurry is a reason to communicate clearly with the senior crew member, not to skip the defect response. Familiarity can encourage the assumption that a previously harmless mark is harmless again. Describe this finding afresh. Pressure and complacency are human-factor topics in FAA AC 120-72A section 5; AMC 20-22 Appendix C, Module A1(e), includes human factors in electrical safety.

Worked situation

An open access area contains wiring beside a service task. One cable has visible outer damage, but nobody knows whether the circuit is energised.

Decision
Keep clear and request the required electrical-safety response.
Reasoning
A nearby switch position cannot establish the state of unidentified wiring. Report what is visible; probing or moving the cable adds electrical and mechanical exposure.

Regulatory basis: what this course includes

This course teaches the sources below as amended up to the act or decision shown. Anything published after it is not part of this edition of the course.

Each source and the amendment, edition or decision this course includes
SourceIncluded up to
AMC 20-22 (EWIS training), Target Group 8AMC-20 Amendment 23 (ED Decision 2022/001/R) (AMC 20-22 unchanged since ED Decision 2008/007/R)

Checked against the official texts on 2026-11-17. Before relying on a point at work, check the current consolidated text on EUR-Lex and the AMC & GM currently published by EASA, including any later ED Decision.

Mid-course quiz Ungraded practice

Application: Electrical safety and role boundaries

3 questions · Retry freely · Separate from your final exam

Choose an action, check its consequence and explore the alternatives. Your practice answers are not saved.

Your scenario · Fictional training example

An open access area contains wiring beside a service task. One cable has visible outer damage, but nobody knows whether the circuit is energised.

Role
Cabin crew
Learning objective
Recognise an electrical hazard and preserve safety without unauthorised intervention.
A nearby unit is switched off. What should happen before the damaged cable is handled?
Compare all answers and explanations

Keep clear and request the required electrical-safety response. — Best choice.
The circuit is unidentified. A switch position is not evidence of isolation. See Lesson 1; AMC 20-22 Appendix C, Module A1(c).

Use the dark unit indication to confirm that its wiring is safe to move. — Consider the consequence.
A function can be off while its supply remains connected. The indication does not establish the cable’s electrical state.

Use a dry cloth to move the cable clear of the open access area. — Consider the consequence.
A cloth does not establish isolation or make exploratory handling part of cabin duties.

Why should a nearby wiring bundle not be used to steady a person?
Compare all answers and explanations

The person’s load is acceptable if a supported bundle returns to its former position. — Consider the consequence.
Returning to position does not rule out concealed damage or show the load was acceptable.

The person’s load can be shared safely by spreading the grip across several clamps. — Consider the consequence.
Spreading the load does not make the wiring an access support.

The person’s load can damage clamps or connections beyond the visible run, despite the bundle springing back. — Best choice.
AMC 20-21 section 11(k) advises against using bundles as handholds, steps or supports. Use the proper access arrangements.

Which instruction should govern a tripped circuit-protection device?
Compare all answers and explanations

The reset instruction used successfully on a similar cabin installation. — Consider the consequence.
Another installation or event may have different precautions; past success does not determine the action here.

The aircraft and operator’s procedure for the particular operating circumstances. — Best choice.
A reset can re-energise a fault. The response must follow the relevant procedure. See Lesson 1; FAA AC 120-80B section 17.

The equipment-use instruction for restarting after a routine power interruption. — Consider the consequence.
A protection trip may indicate a fault; it is not equivalent to a routine loss of supply.

Continue with lesson 2: Recognising abnormal wiring conditions

€19 per seat + VAT where applicable

Get the syllabus by email

Not ready to buy? We email you the printable syllabus, the free lesson and the course page.

Continue?

Help & feedback

Get guidancePrepared answers about buying, learning and certificates.

For questions about lesson content, open Ask Metis inside that lesson.

Submitted feedback is stored. If you request a reply, your reply email is stored.